How it works
How does an external gear positive displacement pump work?
Two gears rotate inside a precision-machined body. On the suction side the teeth separate and create a vacuum; in the transport phase the fluid is trapped between teeth and body; on the discharge side the teeth mesh again and expel the fluid. Each revolution moves a defined volume.
What is the difference between a gear pump and a centrifugal pump?
A gear pump is positive displacement and self-priming: each revolution moves a defined volume, so flow is proportional to shaft speed. Centrifugal pumps lose efficiency with dense fluids, whereas with viscous fluids the product itself lubricates the internal surfaces and improves sealing.
Is the flow pulsating?
No, the flow is practically free of pulsation, with a steady and regular delivery. This matters, for example, with bitumen emulsions, which need minimal pulsation so they do not break, and in any plant where a stable flow makes regulation simpler.
Flow rate and speed
What does the flow rate of a gear pump depend on?
Mainly on rotation speed: flow is proportional to revolutions, because each turn moves a constant volume. The chosen model, the fluid viscosity and the discharge pressure also play a part. The data for each model are listed in the tables of each series.
Does the flow rate change if discharge pressure increases?
Partly, yes: actual flow is partially affected by discharge pressure. With viscous fluids the reduction is minimal, while with volatile fluids it is more significant. In any case, the behaviour is not comparable to that of a centrifugal pump.
Can I regulate the flow rate with an inverter?
Yes. Varying the rotation speed with an inverter gives you the instantaneous flow rate you need, because flow is proportional to revolutions. With abrasive liquids it is best to run at low speed, and the maximum speeds given for each model must always be respected.
Can I use a gear pump for dosing?
An inverter lets you set the instantaneous flow rate by changing the speed. Dosing, meaning delivering a precise quantity and stopping at the right moment, is instead the job of the plant control system, which commands start and stop. The pump provides a stable, regular flow for the system to work with.
Installation
Is the pump self-priming?
Yes. During the suction phase the teeth separate and create a vacuum that draws the fluid in from the tank, with no external priming. This is an important difference from lobe and screw pumps, which are self-priming only in theory. Dry running remains acceptable for very short periods only.
Is a gear pump reversible?
Yes, all CR, SB, NAV and ZV series are reversible: reversing the direction of rotation reverses the flow, which is useful for emptying a line or a tank. The exception is the FX series, the hygienic stainless steel pump, which is not reversible.
Can the pump run dry?
Only for very short periods. The pumped fluid lubricates and cools the internal surfaces, so without liquid the moving parts overheat and wear out quickly. Avoid starting with an empty tank or a closed suction line, and always check that fluid is reaching the pump.
What should the suction line look like?
Short, as straight as possible, with few bends, airtight and of generous diameter. With viscous fluids suction losses increase quickly: an undersized or overly long line fills the pump poorly and encourages cavitation, with loss of flow and wear.
Is a suction filter needed?
It is recommended: a filter on the suction line traps foreign bodies and impurities that could damage gears and body. It must have a mesh suited to the fluid and a large surface area, and be cleaned regularly, because a clogged filter chokes the suction and encourages cavitation.
What is cavitation and how can it be avoided?
If suction pressure drops too far, the liquid evaporates locally and forms bubbles that then collapse inside the pump: noise, vibration, loss of flow and wear. Avoid it with a short, well-sized suction line, a clean filter and a rotation speed suited to the fluid viscosity.
Fluids and materials
Cast iron or AISI 316 stainless steel body?
Cast iron is the solution for most industrial fluids, such as bitumen, oils and resins. AISI 316 stainless steel is chosen for aggressive fluids and for the food, cosmetic and pharmaceutical sectors. The CR series exists in both materials, while the FX is always stainless steel.
From what viscosity does a gear pump make sense?
There is no minimum: even petrol can be pumped. From roughly 50–100 cP upwards, however, a gear pump is practically the only sensible choice: the fluid lubricates the internal surfaces and improves sealing, while centrifugal pumps lose efficiency with dense fluids.
Can abrasive liquids be pumped?
Yes, with the right precautions: materials with surface-hardening heat treatments and a low rotation speed, to limit wear. Filled bitumen is a typical case. Describe the fluid and its abrasive content and we will recommend the suitable configuration.
How is a fluid that solidifies at ambient temperature heated?
With three systems: the thermal oil jacket of the CR series, electric cartridges fitted in the body of a standard pump with a thermoregulator and probe, or the autonomous hot spot, which locally heats the oil of the CR jacket with resistors. The hot spot needs a much longer preheating time than cartridges.
Why choose a gear pump over a lobe or screw pump?
Lobe and screw pumps are not difficult to clean, but they are poor performers: to begin with, they are self-priming only in theory. The external gear pump remains self-priming, with flow proportional to revolutions and practically no pulsation, even with viscous fluids.
Certifications and supply
Are the pumps certified?
Yes. Our quality system has been ISO 9001:2015 certified by SGS since 2004, covering design, production and after-sales service of positive displacement gear pumps. The pumps comply with the Machinery Directive 2006/42/EC (CE marking). Certificates are available on request.
Are ATEX pumps available?
Yes, for zones 1, 2, 21 and 22 and temperature classes T1–T4, with the technical file held at TÜV. Versions for zones 0 and 20 or for temperature classes T5 and T6 are not available. Tell us the zone and temperature class in your enquiry so we can check feasibility immediately.
How quickly do you reply?
We guarantee a technical reply within 24 hours. Write to us through the form or on WhatsApp, stating the fluid, temperature, viscosity, flow rate and pressure required: the more data you give us, the more precise and prompt our recommendation will be for your application.
Can I replace a pump from another manufacturer?
Yes. Send us a photo of the nameplate of the pump to be replaced, together with the working conditions: our Bologna workshop identifies the model in our range suited to take its place and replies within 24 hours. If no catalogue model fits, we will evaluate a custom pump.
Do you build custom pumps?
Yes, when the model is not in the catalogue. We design and machine every component in our own Bologna workshop, since 1955, with our long-standing collaboration with the Institute of Machines of the University of Bologna. Describe your fluid and operating conditions and we will assess the solution together.